4. ERROR DISPLAY
ERROR
SINGAL
ERROR CAUSE COUNTERPLAN
① inlet valve broken Change the Inlet-Valve
IE
WATER ② drain motor working during water supply Change the Drain Motor
INLET ERROR ③ pressure switch disorder Change the Sensor Pressure
④ PCB can not check water level Change the PCB
① drain motor out of order Change the Drain Motor
OE
DRAIN ② inlet valve working during drain Change the Inlet-Valve
ERROR ③ pressure switch disorder Change the Sensor Pressure
④ PCB can not check water level Change the PCB
UE UNBALANCE ERROR ① laundry unbalance rearrange the laundry
① door opened during processing Clode the Door
LE
DOOR
② LOCK S/W broken Change the LOCK SW
OPEN ERROR
③ PCB can not check door lock Change the PCB
① continuous water supplyChange the Inlet-Valve
E2 Overflow ② drain motor can not work Change the Drain Motor
③ pressure switch disorder Change the Sensor Pressure
E3
FAN MOTOR
① fan motor cannot work Change the Fan-Motor
disorder
② PCB cannot control fan motor
The contact of the Connector or Change the PCB
E4
LEAKAGE ① Water leaks from the tub or the drain hose.
Check the leak of the tub or the drain hose
ERROR Then change the tub or drain hose.
① huge noise re-installation
E5
HIGH VOLTAGE
② spining with jamming clothes between gasket rearrange the laundry
ERROR
③ PCB broken Change the PCB
① huge noise re-installation
E6 EMG ERROR
② spining with jamming clothes between gasket rearrange the laundry
③ motor broken Change the Motor
④ PCB broken Change the PCB
E7 Direction Error
① move opposite direction
② motor Hall IC broken check the connector and change
E8 motor disorder
① connector problem The contact of the Connector
② abnormal loading condition check the loading condition and change
E9
SENSOR PRESSURE
① abnormal water level Change the Sensor Pressure
ERROR
H1
sensor temp.
① sensor temp broken Change the Sensor Temp.
dry disorder
② connector problem The contact of the Connector
H2
sensor temp.
① sensor temp. of washing broken Change the Sensor Temp.
wash disorder
② connector problem The contact of the Connector
H3
overheating
① fan motor cannot spin Change the Fan Motor
dry heater
② sensor temp. of dry broken Change the Sensor Temp.
H4
overheating
① heater working with no water supply check water level
wash heater
② sensor temp. of wash broken Change the Sensor Temp.
H6 abnormal of washing heater ① washing heater cannot work Change the Heater Wash
H7 abnormal of drying heater ① dry heater cannot work Change the Heater Dry
H8
abnormal of sensor temp.
① heater working with no water supply
check the water level and washing heater
of washing