Daewoo KUD-UD121WCW Manual de servicio Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
55
SWITCH THERMOSTAT(BIMETAL)
function : control the duct temperature, if the temp reached over 150°C, all power supply will be cut. and if the temp go down
120°C the power will be ON.
protecting overheating by cutting off heater power supply if the temperature rises over 150°C, and reoperating heater
by connecting heater power supply if the temperature falls under 120°C.
• OPERATING TEMPERATURE • PICTURE
UNIT FAN MOTOR
function : circulating the inside air during dry process.
• SPEC • PICTURE
• FAILURE MODE : * E3 shown : FAN MOTOR cannot work.
• CHECKING METHOD : Check the FAN MOTOR is short, and replace with new one.
OPEN TEMPERATURE(OFF) 150°C ± 5°C
CLOSE TEMPERATURE(ON) 120°C ± 5°C
ITEMS SPEC
RATING VOLTAGE 24V
RPM
MOTOR 3700 ± 10%
DUCT FAN AS 1900 ± 10%
ROTAING DIRECTION CW
Vista de pagina 56