9h
Setting the limit stops for the two-wing version - gate 1 (gate must be in "open" position)
Press button "P"
Press button "P"
Press button "P" for 2 seconds
"F" is indicator
LED lights up
LED flashes
"E" is indicator
LED or flashes
Press button and keep it depressed until the gate has reached the final "CLOSE" position.
Fine adjustment an be made by briefly pressing button or button which increases or reduces the travel distance
of the gate by approx. 4 mm, without the gate moving!
The final "CLOSE" position (limit stop) is stored.
Press button and keep it depressed until the gate has reached the final "OPEN" position.
Carry out fine adjustment as described above.
The final "OPEN" position (limit stop) is stored.
"OPEN" direction
"CLOSE" direction
Programming is completed.
Press button "P"
LED lights up
Press button "P" only with
autom. timed return
Press button "P"
Press button "P"