page 26
9k
9l
Indicator 7 to 8:
Setting the "prewarning" or "gate open time" in accordance
withfig. 9n.
Connection of red traffic light H20 to terminal 1 and N (X2b
as per fig. 7)
Press button "P" and at the same time switch on the mains.
"c" appears in the indicator.
Indicator
9n
Cancelling the settings
Programm the type of operation
5 -B55 Impulse/stop/impulse in opposite direction
6 -B5/B6 Impulse open/close (directional control)
7 -B5/B6
Open/close with self-hold and autom.timed return
8 -B5/B6 Open/close with self-hold and autom.timed
return after driving past the site photocell
B55/B5/B6, B5/B6 with autom. timed return (pre-programmed
at the factory for sequential phase control B55 - only alter if
required).
Programming
Press button and at the same time switch on the mains.
Selection via button , and storage of selected setting via
button "P" (after 30 seconds storage is automatic).
Programming the light relay K6
1 3-minute light phase
2 Flashing pulse
3 Gate operational
(pre-set at the factory for 3-minute light phase,
only alter ifrequired).
Programming
Press button and at the same time switch
on the mains.
Select via button and store selected setting
by pressing button "P" (after 30 seconds
storage is automatic).
Connect up site lighting, flashing light or
beacon in accordance with the circuit dia-
gram.
Function messages Fault messages
Indicator Function Indicator Indicator Fault
0 Stop button 8 Reference contact without function motor 1 /
2 Impulse OPEN (button/remote control) 9 Hybrid photocell (speed registration) w/out function motor 1
4 Impulse CLOSE (button/remote control) 10 Power limit motor 1
6 Driveway photocell 11 Operation time limitn
7 Programming abrupted 16 Safety device testing not o.k.
17 Reference contact without function motor 2
18 Hybrid photocell (speed registration) w/out function motor 2
19 Power limit motor 2
Indicator for operating mode
Indicator for operating mode 2 to 6
2 Flashing light
3 Revolving beacon
Indicator for operating mode 7, 8, 9
9m