Daewoo RFS-26D1 Series Guía de instalación Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 67
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
12
4-2. Control of ice maker room
4. OPERATION AND FUNCTIONS
INPUT CONTROL OBJECT
CONTENTS REMARKS
I DUCT/ F/ R Sensor
Flow Sensor
Freezer Set
Compressor
R-ice Fan
1. Ice Room Sensor on/off Setting Value of Ice maker room
2. Ice storage mode : After 1 hour detect full Ice switch and when Five times of consecutive
water supply failure to Ice Maker.
3. Ice Make mode : Enter it 120 minutes during Ice storage mode later that RT 15 under
4. R-ice Fan are Close of Deforst Mode
5. Comp and R-ice Fan turn On about 10 hours of Quick Ice Mode
Ice storage
mode
Ice make mode Precool
RT<59
(15)
59(15) <
RT
< 73(23)
73(23)
< RT
RT<59
(15)
59
(15) < RT
ON 16(-9)5(-15)0(-18)1(-17)12(-11)16(-9)
OFF 12(-11)-2(-19)-8(-22)-6(-21)5(-15)9(-13)
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 66 67

Comentarios a estos manuales

Sin comentarios