Daewoo RFS-26D1 Series Guía de instalación Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 67
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
19
Compensation of R-sensor ON/OFF temp. (down)
In case temperature of refrigerator compartment is weak or insufficient,
take the following action.
INPUT CONTROL OBJECT
CONTENTS REMARKS
Main PCB
Resistance of R-sensor
ON/OFF Temp. of Refrigerator
R42 : R-SENSOR standard resistance in normal mode (31.4)
In case of weak ref.
1) Cut J1 to increase the standard resistance by 2㏀⇒3 down
2) Cut J1 & J2 to increase the standard resistance by 4㏀⇒6 down
4-11. Compensation of R-sensor ON/OFF Temp.
R-SENSOR
J2
R42
(31.4)
R43
(2)
R44
(4)
J1
J1 - cut - cut
J2 - - cut cut
Temperature
compensation
0
-3
0
-6
Resistance
R42 R42+R43 R42 R42+R43+R44
31.4
(31.4+2)
31.4
(31.4+2+4)
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 66 67

Comentarios a estos manuales

Sin comentarios