1. A/S Defrosting Mode (Heater defrost Pause Fan Delay)
INPUT CONTROL OBJECT
CONTENTS REMARKS
1. Defrosting Cycle
Heater
Defrosting
1) Comp, F/R-ICE/C Fan : OFF
R Damper : CLOSE
FD/RD-Heater : ON
2) Time limit
30 seconds : Heater is ON regardless of FD/RD-sensor
temperature right after defrosting start
30 minutes : in case of FD/rD-Error
50 minutes : in normal control state
3) If FD-sensor 55.4, F Heater Defrosting is OFF
If RD-sensor 55.4, R Heater Defrosting is OFF
Pause
Time : 7 minutes
Comp, F/R-ICE/C Fan, Damper, Heater etc. : OFF
Fan-Delay
1) Time : 5 minutes
Comp, C Fan : ON
F/R-ICE Fan, Damper, Heater : OFF
Pause
Fan-Delay
Heater
Defrosting
2. How to start
; In “Lock” mode, push “Frideg Set” button 5 times while pushing “Freezer Set
button simultaneously.
3. How to proceed
1) same as normal defrosting
2) Heater is ON regardless of FD/RD-sensor temp. at first 30 seconds.
(Check of defrosting current)
4-4. Forced Defrosting Mode
1. Fan voltage of control mode
INPUT CONTROL OBJECT
CONTENTS REMARKS
1. F-Sensor
2. R-Sensor
1. F FAN, R-ICE FAN, C FAN
FAN Freezer R ICE Condenser
Voltage 13 V 13 V 13 V
4-5. Fan Voltage of Control Mode
1. Comp
2. F/R-ICE/C Fan
3. FD/RD Heater