Daewoo RFS-26D1 Series Guía de instalación Pagina 39

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 67
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 38
38
Refer to error display
in operation and function
Start
Change the
Comp.
Change Temp-Fuse
Y
N
N
Y
N
Y
Y
N
Y
N
Change OLP/PTC
Change the
defective motor
Change Main PCB
Check lead wire
Change the
Defrost heater.
Check ice formation on Eva.
and if refrigerant leak
is found, repair it.
N
N
Y
Y
Y
N
N
Defrost heater : 200W ( 66)
(Left & Right side of Evaporator)
Left & Right side of evaporator
OLP/PTC
is OK?
Does Comp.
work?
Any error code
on Front PCB?
F-Fan & C-Fan
work ok?
F-Fan & C-Fan
motor is ok?
Wiring connection
is ok?
Temp-Fuse is ok?
(on the evaporator)
Defrost heater
Is ok?
Ice formation on Eva.
is ok?
Y
8-2-1. Freezing failure . (Foods are not frozen / cold.)
8-2. Freezer Compartment
Vista de pagina 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 66 67

Comentarios a estos manuales

Sin comentarios