(2) Electronic gear command pulse accumulation[symbol C, -600000 pulse 600000 pulse]~
- Display count amount of the position command input pulse after electronic gear is adapted.
- If the set button pressed, Reset in “0”.
- Accumulated values of the reverse pulses light up all dot mark.
C6.0.0.0.0. C0C60000
CW CCW
(3) Feedback Pulse accumulation [symbol b, -600000 Pulse 600000 Pulse]~
- After servo ready, Display count amount of the moving of the motor. If count excess
600000, Resume from " 0 ".
- If the set button pressed, Reset in “ 0 ”.
- Accumulated values of the reverse pulses light up the dot mark.
b. 6. 0. 0. 0. 0. b0b60000
CW CCW
(4) Residual pulse [symbol E, -600000 pulse 600000 pulse]~
- Display residual pulse of the position deviation counter.
- Reverse pulses light up the dot mark.
E6.0.0.0.0. E0E60000
CW CCW
(5) Command pulse frequency [symbol F, -400Kpps 400Kpps]~
- Display frequency of the position command input pulse[min units: 100 pps ( 0.1 Kpps )]
- This is a value before select electronic gear (pulse multiplying factor)[CW pulse:(-)]
F-200. F.1F 200.
CW 200Kpps CCW 100pps CCW 200Kpps
(6) Rotation speed of the motor [symbol r, -3000 rpm 3000 rpm]~
- Display rotation speed of the motor( CW : (-), CCW : (+) )
r-3000 r0r 3000
CW CCW